Loading Port:China main port
Payment Terms:TT OR LC
Min Order Qty:10 pc
Supply Capability:1000 pc/month
. Smart Remote Control (RMT)
. Battery Temperature Sensor (BTS)
. Automatic Generator Starting (AGS)
. Support Solar Panel with MPPT Function
. Designed to Operate under Harsh Environment
. DC Start & Automatic Self-Diagnostic Function
. Compatible with Both Linear & Non-Linear Load
. Easy to Install & Easy to Operate & Easy to Solve
Model | 8.0KW | 10.0KW | 12.0KW | |
Inverter Output | Continuous Output Power | 8.0KW | 10.0KW | 12.0KW |
Surge Rating(20ms) | 24.0KW | 30.0KW | 36.0KW | |
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | |||
Nominal Efficiency | >88%(Peak) | |||
Line Mode Efficiency | >95% | |||
Power Factor | 0.9-1.0 | |||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||
Output Voltage Regulation | ±10% RMS | |||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||
Short Circuit Protection | Yes( 1sec after fault ) | |||
Typical transfer Time | 10ms(Max) | |||
THD | < 10% | |||
DC Input | Nominal Input Voltage | 12.0Vdc | ||
( *2 for 24Vdc, *4 for 48Vdc) | ||||
Minimum Start Voltage | 10.0Vdc | |||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||
Low Battery Trip | 10.0Vdc / 10.5Vdc | |||
High Voltage Alarm | 16.0Vdc | |||
Low Battery voltage recover | 15.5Vdc | |||
Idle Consumption-Search Mode | < 25 W when Power Saver On | |||
Charger | Output Voltage | Depends on battery type | ||
Charger Breaker Rating | 40A | |||
Max Charge Power Rate | 1/3 Rating Power | |||
Battery Initial Voltage for Start Up | 10-15.7V for 12V( *2 for 24V, *4 for 48V) | |||
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) | |||
Remote Control | Yes(Optional) | |||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||
Nominal Voltage | 230Vac | |||
Max Input AC Voltage | 150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; | |||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||
Overload protection(SMPS load) | Circuit breaker | |||
Output Short circuit protection | Circuit breaker | |||
Bypass breaker rating | 50A | 63A | 63A | |
Transfer switch rating | 80amp for UL | |||
Bypass without battery connected | Yes (Optional) | |||
Max bypass current | 80amp | |||
Solar Charger (Optional) | Rated Voltage | 12Vdc / 24Vdc / 48Vdc | ||
Solar Input Voltage Range | 15-30Vdc / 30-55Vdc / 55-100Vdc | |||
Rated Charge Current | 40 ~ 60A | |||
Rated Output Current | 15A | |||
Self Consumption | < 10mA | |||
Bulk Charge(Default) | *2 for 24Vdc, *4 for 48Vdc | |||
Floating Charge(Default) | ||||
Equalization Charge(Default) | ||||
Over Charge Disconnection | ||||
Over Charge Recovery | ||||
Over Discharge Disconnection | ||||
Over Discharge Reconnection | ||||
Temperature Compensation | ||||
Ambient Temperature | 0 ~ 40°C(Full load) 40 ~ 60°C(Derating) | |||
Mechanical Specifications | Mounting | Wall Mount | ||
Inverter Dimensions(L*W*H) | 588*415*200mm | |||
Inverter Weight(Solar Chg)KG | 60+2.5 | 66+2.5 | 70+2.5 | |
Shipping Dimensions(L*W*H) | 750*520*310mm | |||
Shipping Weight(Solar Chg)KG | 62+2.5 | 68+2.5 | 72+2.5 | |
Display | Status LEDs / Status LEDs+LCD | |||
Standard Warranty | 1 Years (Optional) |
Warranty
provides a 1~3 year limited warranty (“Warranty”) against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers, Solar charge controllers, Battery Products (“Product”).
The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration card submitted to MUST-Solar. This Warranty applies to the original MUST-Solar Product purchaser, and is transferable only if the Product remains installed in the original use location.
FAQ
1. How do I decide which system is right for me ?
For protection from long outages, include a generator or solar panels in your Must solar system. Shorter outages can be handled by a battery-only system.
2. Where my system will be installed ?
Must solar systems are usually wall-mounted near a home's main electrical (circuit breaker) panel.
3. How do I install my system ?
A must solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .