Loading Port:Qingdao
Payment Terms:TT OR LC
Min Order Qty:1000 m
Supply Capability:50000 m/month
Product Name:Polyethylene raised temperature resistance (PE-RT) for floor heating
Standard:CJ / T175-2002
Pipe series:S6.3/S5/S4/S3.2/S2.5
Application:Floor heating
PE-RT pipe for floor heating
Product Name:Polyethylene raised temperature resistance (PE-RT) for floor heating
Specification:
Nominal outside diameter (mm)
| mean outside diameter(mm) | round(mm) | Pipe series | ||||||
Outside diameter |
tolerance |
Straight pipe |
Coil pipe | S6.3 | S5 | S4 | S3.2 | S2.5 | |
wall thickness(mm) | |||||||||
12 | 12.0 | 0.3 | ≦1.0 | ≦1.0 | ---- | ---- | ---- | ---- | 2.0 |
16 | 16.0 | 0.3 | ≦1.0 | ≦1.0 | ---- | ---- | 2.0 | 2.2 | 2.7 |
20 | 20.0 | 0.3 | ≦1.0 | ≦1.2 | ---- | 2.0 | 2.3 | 2.8 | 3.1 |
25 | 25.0 | 0.3 | ≦1.0 | ≦1.5 | 2.0 | 2.3 | 2.8 | 3.5 | 4.2 |
32 | 32.0 | 0.3 | ≦1.0 | ≦2.0 | 2.4 | 2.9 | 3.6 | 4.4 | 5.4 |
40 | 40.0 | 0.4 | ≦1.0 | ≦2.4 | 3.0 | 3.7 | 4.5 | 5.5 | 6.7 |
50 | 50.0 | 0.5 | ≦1.2 | ≦3.0 | 3.7 | 4.6 | 5.6 | 6.9 | 8.3 |
63 | 63.0 | 0.6 | ≦1.6 | ≦3.8 | 4.7 | 5.8 | 7.1 | 8.6 | 10.5 |
75 | 75.0 | 0.7 | ≦1.8 | ---- | 5.6 | 6.8 | 8.4 | 10.3 | 12.5 |
90 | 90.0 | 0.9 | ≦2.2 | ---- | 6.7 | 8.21 | 10.1 | 12.3 | 15.0 |
110 | 110.0 | 1.0 | ≦2.7 | ---- | 8.1 | 10.0 | 12.3 | 15.1 | 18.3 |
125 | 125.0 | 1.2 | ≦3.0 | ---- | 9.2 | 11.4 | 14.0 | 17.1 | 20.8 |
140 | 140.0 | 1.3 | ≦3.4 | ---- | 10.3 | 12.7 | 15.7 | 19.2 | 23.3 |
160 | 160.0 | 1.6 | ≦3.9 | ---- | 11.8 | 14.6 | 17.9 | 21.9 | 26.6 |
Physical Performance:
Item | test Hoop stress/MPa | Test temperature℃ | Test time h | index |
Longitudinal reversion rate | ---------- | 110 | en≦8mm 1 8mm en>16mm 3 | <3%< span=""> |
Hydrostatic test | 10.00 | 20 | 1 | no rupture no leakage |
3.55 | 95 | 165 | ||
3.50 | 95 | 1000 | ||
Thermal stability test under hydrostatic state | 1.90 | 110 | 8760 | no rupture no leakage |
Flow rate of Melt quality.MFR(190℃,2.16kg) g/10min change rate ≦30% of material |
Application of polyethylene (PE-RT) pipe for hot and cold water resistant
1. The floor heating system
2. hot and cold water supply systems in building
3. floor heating pipes with special needs, such as airport runways and city roads snowmelt pipeline
4.The high temperature radiator heating, residential central heating
5. Domestic hot water systems and various types of connecting pipes
6. The fluid pipeline of food industry like beverages, alcohol and other
7. The cooling system and water treatment system piping
8. Other industrial pipes