EPDM shield rubber compound for medium voltage cable

Loading Port:Shanghai

Payment Terms:TT OR LC

Min Order Qty:-

Supply Capability:3000 Tons kg/month

Product Description:

EPDM shield rubber compound for medium voltage cable

I.     Type and application

Type

Product

Application

XB-34A

90 Shield rubber compound for medium voltage cable

Unpeelable shield rubber compound  for 630KV medium voltage cables and wires

XB-34B1

90 Shield rubber compound for medium voltage cable

Inner shield rubber compound for  6/10KVmedium voltage cables and wires

XB-34K1

90 Peelable shield rubber compound for medium voltage cable

Peelable outer shield rubber  compound for 6/10KVmedium voltage cables and wires

XB-34B2

90 Shield rubber compound for medium voltage cable

Inner shield rubber compound for  8.5/15KV medium voltage cables and wires

XB-34K2

90Peelable shield rubber compound for medium voltage cable

Peelable outer shield rubber  compound for 8.5/15KV medium voltage cables and wires

II.   Product description

XB series shield rubber compound for medium voltage cable, based onEPDM rubber, is mixed with various additives, and is elaborated in theextra-clean conditions. The compound has outstanding performances of vulcanization, processing, electricconduction and shield properties. The compound is complied withQ/320585JSDT058-2003 standard.

III.  Processing

Processing Equipment

Compression ratio

L/D

Processing temp.

Recommended vulcanize  temp.

Common rubber extruder

1.111.51

51201

60110

160-200℃

 

IV.   Maximum useful shelf life

12 months at 20℃, 6 months at 30℃.

V.     Properties

Table

Item

XB-34A

XB-34B1

XB-34K1

XB-34B2

XB-34K2

Standard

Typical

Standard

Typical

Standard

Typical

Standard

Typical

Standard

Typical

Tensile Strength N/mm2

≥7.0

10.1

≥7.0

10.4

≥7.0

9.0

≥7.0

11.2

≥7.0

9.6

Elongation at Break %

≥200

472

≥200

430

≥200

420

≥200

460

≥200

440

Oven  aging

Aging condition 135℃168h

Tensile Strength N/mm2

10.6

10.6

9.3

12.0

10.6

Variation  %

±20

+5

±20

+2

±20

+3

±20

+7

±20

+10.4

Elongation at Break %

450

400

400

450

410

Variation %

±30

-4

±30

-7

±30

-5

±30

-2

±30

-7

Hot Prolongation

Testing Temp. 200℃

Conditions 15min20N/cm2

Elongation Under Load %

≤175

70

≤175

50

≤175

60

≤175

60

≤175

70

Permanent  Elongation after cooling %

≤15

10

≤15

0

≤15

10

≤15

0

≤15

10

Volume Resistivity at20Ωcm

≤100

8

≤100

43

≤100

45

≤100

25

≤100

30