Loading Port:China main port
Payment Terms:TT or LC
Min Order Qty:10 carton
Supply Capability:20000 carton/month
EA500KTS/M / EA630KTM/X
The central inverter with external transformer adopts high power density design to be smaller size and optical fiber isolation technology to have strong anti-jamming capability, and also integrates DC distribution cabinet function to be more suitable for big power plant; and. It offers different output voltage options
● Low-voltage and zero-voltage ride through to cope with various grid conditions
● Nighttime SVG function, ready for power compensation full time
● Adjustable active power, power factor adjustment from 0.9 overexcited to 0.9 underexcited
● Max. Efficiency at 98.7% (without transformer)
● Advanced MPPT algorithm
● Anti-islanding
● Wide DC input voltage, easy to make the combination of PV array
● CQC certificates (pass CQC33-461239-2013ma test), TÜV certificates, CE certificates
Specification / Type | EA500KTS | EA500KTM | EA630KTM | EA630KTX |
Input (DC) | ||||
Max DC Voltage | 1000Vdc | 1000Vdc | 1000Vdc | 1000Vdc |
Full-load MPPT Voltage Range | 450~820Vdc | 500~850Vdc | 500~850Vdc | 500~850Vdc |
Max DC Power | 550KWp | 550KWp | 630KWp | 630KWp |
Max DC Current | 1200A | 1100A | 1260A | 1200A |
Number of DC Inputs | 16 | 16 | 16 | 16 |
Output (AC) | ||||
Nominal AC Power | 500KW | 500KW | 630KW | 630KW |
Nominal AC Voltage | 270Vac | 315Vac | 315Vac | 400Vac |
AC Voltage Range | 210~310Vac | 245~362Vac | 245~362Vac | 312~460Vac |
Nominal Frequency | 50Hz/60Hz | |||
Frequency Tolerance Range | 47-51.5Hz/57-61.5Hz | |||
Distortion (THD%) | <3%(at nominal power) | |||
Power Factor (Cos phi) | 0.9(leading)~0.9(lagging) | |||
System Parameters | ||||
Max Efficiency | 98.7% | |||
Euro Efficiency | 98.5% | |||
Protection Degree | IP20 (indoor) | |||
Night Consumption | <100W | |||
Operation Temperature Range | -25℃~+55℃ | |||
Cooling | forced-air cooling | |||
Relative Humidity | 0-95%, no condensation | |||
Max Working Altitude | 2000m (derating above 3000m) | |||
Display and Communication | ||||
Display | LCD | |||
Standard Communication | RS485 | |||
Optional Communication | Ethernet /USB | |||
Structure Parameters | ||||
Dimensions(W×D×H) | 1800×800×2200mm | |||
Weight | 1500kg |
· Q. What is an UPS and What it is for ?
An uninterruptible power supply (UPS) is a device that allows your computer or telephone switch or critical equipement to keep running for at least a short time or longer time when the primary power source is lost. It also provides protection from power surges, spikes, brownouts, interference and other unwanted problems on the supported equipment.
· Q. How long the UPS to run when power goes?
This can take 3 paths.
1.You can pick a UPS that is rated for pretty much the full VA you need so it will be running at 100% of capability and will thus last 'n' minutes.
2.You can pick a UPS that is rated at a much higher VA value than you really need so, for example, is running at 50% of capability and will thus last for longer than the UPS from option 1.
3.You can use extra external battery packs to run for longer. If charging capability allows, the more and the bigger batteries you take with, the longer time UPS runs.
or using a generator after about 6 hours, it will be more cost-effective, with a short runtime UPS to bridge the generator start-up gap.