MODEL | EP3000 Series 1-3KW | ||||||
EP3000 | 1012E | 1512E | 2012E | 2024E | 3012E | 3024E | 3048E |
LINE MODE SPECIFICATIONS: | |||||||
Input Voltage Waveform | Sine wave (utility or generator) | ||||||
Nominal Input Voltage | 230Vac(120VAC selectable) | ||||||
Low Line Disconnect | 155Vac±2% | ||||||
Low Line Re-connect | 164Vac ±2% | ||||||
High Line Disconnect | 272Vac±2% | ||||||
High Line Re-connect | 265Vac±4% | ||||||
Max AC Input Voltage | 270Vrms | ||||||
Nominal Input Frequency | 50Hz/ 60Hz(Auto detection) | ||||||
Low Line Frequency Re-connect | 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz; | ||||||
Low Line Frequency Disconnect | 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz; | ||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz; | ||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz;55+0.3Hz for 50Hz; | ||||||
Output Voltage Waveform | As same as Input Waveform | ||||||
Over-Load Protection(SMPSload) | Circuit breaker | ||||||
Output Short Circuit Protection | Circuit breaker | ||||||
Efficiency (Line Mode) | >95% | ||||||
Transfer Switch Rating | 30A | ||||||
Transfer Time (Ac to Dc) | 10ms (typical) | ||||||
Transfer Time (Dc to Ac) | 10ms (typical) | ||||||
Pass Through Without Battery | Yes | ||||||
Max Bypass Overload Current | 30A | ||||||
INVERT MODE SPECIFICATIONS: | |||||||
Output Voltage Waveform | Sine wave | ||||||
Rated Output Power (VA) | 1000 | 1500 | 2000 | 2000 | 3000 | 3000 | 3000 |
Rated Output Power (W) | 1000 | 1500 | 2000 | 2000 | 3000 | 3000 | 3000 |
Power Factor | 0~1.0 | ||||||
Nominal Output Voltage (V) | 230Vac | ||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | ||||||
Auto Tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz | ||||||
Output Voltage Regulation | ±10% rms | ||||||
Nominal Efficiency | >80% | ||||||
Over-Load Protection(SMPS load) | (110%150% ±10%:Fault (shutdown output) after 20s; | ||||||
Surge Rating (10s) | 3000VA | 4500VA | 6000VA | 6000VA | 9000VA | 9000VA | 9000VA |
Capable Of Starting Electric Motor | 1 HP | 1 HP | 1 HP | 1 HP | 2HP | 2 HP | 2 HP |
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||||
Inverter Breaker Size | 10A | 10A | 30A | 30A | 30A | 30A | 30A |
Nominal DC Input Voltage | 12V | 12V | 12V | 24V | 12V | 24V | 48V |
Min DC Start Voltage | 10V/20V/40V | ||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery | ||||||
Low DC Input Shut-Down | 10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery | ||||||
High DC Input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery | ||||||
High DC Input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery | ||||||
Power Saver | Load ≤25W (Enabled on "P/S auto" setting of Remote control) | ||||||
CHARGE MODE SPECIFICATIONS: | |||||||
Nominal Input Voltage | 230Vac | ||||||
Input Voltage Range | 165V-265V | ||||||
Nominal Output Voltage | According to the battery type | ||||||
Nominal Charge Current | 35A | 45A | 65A | 35A | 75A | 45A | 30A |
Charge Current Regulation | ± 5Adc | ||||||
Battery Initial Voltage | 0 –15.7 Vdc/31.4Vdc/62.8Vdc (can operate with 0V battery) | ||||||
Charger Short Circuit Protection | Circuit breaker | ||||||
Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc/62.8Vdc,beeps 0.5s every 1s & fault after 60s | ||||||
GENERAL SPECIFICATIONS: | |||||||
Safety Certification | CE | ||||||
Operating Temperature Range | 0°C to 40°C | ||||||
Storage Temperature | 15°C below zero to 60°C | ||||||
Operation Humidity | 5% to 95% | ||||||
Audible Noise | 60dB max | ||||||
Cooling | Forced air, variable speed fan | ||||||
Size | 1012E/1024E/2012E/2024E/2048E | ||||||
3012E/3024E/3048E: | |||||||
G.W | 1kw-20KG 1.5kw,2kw-23KG 3kw-28KG |
Warrenty
provides a 1~3 year limited warranty (“Warranty”) against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers, Solar charge controllers, Battery Products (“Product”).
The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration card submitted to MUST-Solar. This Warranty applies to the original MUST-Solar Product purchaser, and is transferable only if the Product remains installed in the original use location.
FAQ
1. How do I decide which system is right for me ?
For protection from long outages, include a generator or solar panels in your Must solar system. Shorter outages can be handled by a battery-only system.
2. Where my system will be installed ?
Must solar systems are usually wall-mounted near a home's main electrical (circuit breaker) panel.
3. How do I install my system ?
A must solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .