MODELEP3000 Series 1-3KW
EP30001012E1512E2012E2024E3012E3024E3048E
LINE MODE SPECIFICATIONS: 
Input Voltage WaveformSine wave  (utility or generator)
Nominal Input Voltage230Vac(120VAC selectable)
Low Line Disconnect155Vac±2%
Low Line Re-connect164Vac ±2%
High Line Disconnect272Vac±2%
High Line Re-connect265Vac±4%
Max AC Input Voltage270Vrms
Nominal Input Frequency50Hz/ 60Hz(Auto detection)
Low Line Frequency Re-connect58+0.3Hz for 60Hz;48+0.3Hz for 50Hz;
Low Line Frequency Disconnect57+0.3Hz for 60Hz;47+0.3Hz for 50Hz;
High Line Frequency Re-connect64+0.3Hz for 60Hz;54+0.3Hz for 50Hz;
High Line Frequency Disconnect65+0.3Hz for 60Hz;55+0.3Hz for 50Hz;
Output Voltage WaveformAs same as Input Waveform
Over-Load Protection(SMPSload)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Efficiency (Line Mode)>95%
Transfer Switch Rating30A
Transfer Time (Ac to Dc)10ms (typical)
Transfer Time (Dc to Ac)10ms (typical)
Pass Through Without BatteryYes
Max Bypass Overload Current30A
INVERT MODE SPECIFICATIONS: 
Output Voltage WaveformSine wave
Rated Output Power (VA)1000150020002000300030003000
Rated Output Power (W)1000150020002000300030003000
Power Factor0~1.0
Nominal Output Voltage (V)230Vac
Nominal Output Frequency (Hz)50Hz ± 0.3Hz
Auto Tracking Main Frequency(Hz)Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz
Output Voltage Regulation±10% rms
Nominal Efficiency>80%
Over-Load Protection(SMPS load)(110%150% ±10%:Fault (shutdown output) after 20s;
Surge Rating (10s)3000VA4500VA6000VA6000VA9000VA9000VA9000VA
Capable Of Starting Electric Motor1 HP1 HP1 HP1 HP2HP2 HP2 HP
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Inverter Breaker Size10A10A30A30A30A30A30A
Nominal DC Input Voltage12V12V12V24V12V24V48V
Min DC Start Voltage10V/20V/40V
Low Battery Alarm10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery
Low DC Input Shut-Down10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery
High DC Input Alarm & Fault16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery
High DC Input Recovery15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery
Power SaverLoad ≤25W (Enabled on "P/S auto" setting of Remote control)
CHARGE MODE SPECIFICATIONS: 
Nominal Input Voltage230Vac
Input Voltage Range165V-265V
Nominal Output VoltageAccording to the battery type
Nominal Charge Current35A45A65A35A75A45A30A
Charge Current Regulation± 5Adc
Battery Initial Voltage0 –15.7 Vdc/31.4Vdc/62.8Vdc (can operate with 0V battery)
Charger Short Circuit ProtectionCircuit breaker
Over Charge ProtectionBat. V ≥ 15.7Vdc/31.4Vdc/62.8Vdc,beeps 0.5s every 1s & fault after 60s
GENERAL SPECIFICATIONS: 
Safety CertificationCE
Operating Temperature Range0°C to 40°C
Storage Temperature15°C below zero to 60°C
Operation Humidity5% to 95%
Audible Noise60dB max
CoolingForced air, variable speed fan
Size1012E/1024E/2012E/2024E/2048E
 3012E/3024E/3048E:
G.W1kw-20KG 1.5kw,2kw-23KG 3kw-28KG

2000W Pure Sine Wave InverterTop Selling South Africa CE Approved EP 3000 24V

2000W Pure Sine Wave InverterTop Selling South Africa CE Approved EP 3000 24V

2000W Pure Sine Wave InverterTop Selling South Africa CE Approved EP 3000 24V

 

Warrenty

provides a 13 year limited warranty (“Warranty”) against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers, Solar charge controllers, Battery Products (“Product”).

The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration card submitted to MUST-Solar. This Warranty applies to the original MUST-Solar Product purchaser, and is transferable only if the Product remains installed in the original use location.

 

FAQ

1.    How do I decide which system is right for me ?

For protection from long outages, include a generator or solar panels in your Must solar system. Shorter outages can be handled by a battery-only system.

2.    Where my system will be installed ?

Must solar systems are usually wall-mounted near a home's main electrical (circuit breaker) panel.

3. How do I install my system ?

A must solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .